Supported STONITH Interfaces for HA NFS
The STONITH interfaces are used in the HA NFS cluster to remotely power down NFS servers.
When choosing the STONITH device for the HA NFS cluster, consult the filtered list of supported STONITH interfaces. The source list is available from the heartbeat-stonith-2.1.3-3.el5.centos
RPM package by executing the stonith –L –h
command.
- STONITH Device:
apcmaster
– APC MasterSwitch (via telnet).Note, that the APC MasterSwitch accepts only one (telnet) connection/session a time. When one session is active, subsequent attempts to connect to the MasterSwitch will fail. For more information, see http://www.apc.com/.
List of valid parameter names for apcmaster STONITH device:
ipaddr
login
password
-
STONITH Device:
apcsmart
– APC Smart UPS.The device should be connected by means of a serial port only.
The device works with higher-end APC UPSes, for example: Back-UPS Pro, Smart-UPS, Matrix-UPS, and the like.
See http://www.networkupstools.org/protocols/apcsmart.html for protocol compatibility details. For more information, see http://www.apc.com/.
List of valid parameter names for apcsmart STONITH device:
ttydev
hostlist
-
STONITH Device:
baytech
– Bay Technical Associates (Baytech) RPC series power switches (via telnet).The RPC-5, RPC-3 and RPC-3A switches have been extensively tested for compliance.
For more information, see http://www.baytech.net/.
List of valid parameter names for baytech STONITH device:
ipaddr
login
password
-
STONITH Device:
cyclades
– Cyclades AlterPath PM series power switches (via TS/ACS/KVM).For more information, see http://www.cyclades.com/.
List of valid parameter names for cyclades STONITH device:
ipaddr
login
serialport
-
STONITH Device:
external/ibmrsa
– IBM MP host reboot/poweron/poweroff.For more information, see http://www.ibm.com.
List of valid parameter names for external/ibmrsa STONITH device:
hostname
ipaddr
userid
passwd
type
-
STONITH Device:
external/ibmrsa-telnet
– External STONITH plugin for HAv2 which connects to a RSA board on IBM servers by means of telnet. Commands to turn on/off power and to reset server are sent appropriately.For more information, see http://www.ibm.com/Search/?q=remote+supervisor+adapter.
List of valid parameter names for external/ibmrsa-telnet STONITH device:
nodename
ip_address
username
password
-
STONITH Device:
external/ipmi
– IPMI-based host reset.For more information, see http://ipmitool.sf.net/.
List of valid parameter names for external/ipmi STONITH device:
hostname
ipaddr
userid
passwd
-
STONITH Device:
external/rackpdu
– APC Switched Rack PDU AP7952.For more information, see http://www.apc.com/products/family/index.cfm?id=70.
List of valid parameter names for external/rackpdu STONITH device:
host
community
outlet
-
STONITH Device:
external/riloe
– COMPAQ RILOE STONITH device.For more information, see http://www.hp.com/.
List of valid parameter names for external/riloe STONITH device:
hostlist
ilo_hostname
ilo_user
ilo_password
ilo_can_reset
ilo_protocol
ilo_powerdown_method
-
STONITH Device:
ibmhmc
– IBM Hardware Management Console (HMC).Use for IBM i5, p5, pSeries and OpenPower systems managed by HMC
Optional parameter name managedsyspat is white-space delimited list of patterns used to match managed system names; if last character is '*', all names that begin with the pattern are matched.
Optional parameter name password is password for
hscroot
if passwordless ssh access to HMC has not been setup.For more information, see http://publib-b.boulder.ibm.com/redbooks.nsf/RedbookAbstracts/SG247038.html.
List of valid parameter names for ibmhmc STONITH device:
ipaddr
-
STONITH Device:
nw_rpc100s
– Micro Energetics Night/Ware RPC100S.For more information, see http://www.microenergeticscorp.com/.
List of valid parameter names for nw_rpc100s STONITH device:
ttydev
hostlist
-
STONITH Device:
rcd_serial
– RC Delayed Serial STONITH Device.This device can be constructed cheaply from readily available components, with sufficient expertise and testing.
See README.rcd_serial for circuit diagram.
For more information, see http://www.scl.co.uk/rcd_serial/.
List of valid parameter names for rcd_serial STONITH device:
hostlist
ttydev
dtr|rts
msduration
-
STONITH Device:
rps10
– Western Telematic Inc. (WTI) Remote Power Switch - RPS-10M.For more information, see http://www.wti.com/.
List of valid parameter names for rps10 STONITH device:
serial_to_targets
-
STONITH Device:
wti_nps
– Western Telematic (WTI) Network Power Switch Devices (NPS-xxx).The device also supports the WTI Telnet Power Switch Devices (TPS-xxx).
Note, that the WTI Network Power Switch accepts only one (telnet) connection/session at a time.
For more information, see http://www.wti.com/.
List of valid parameter names for wti_nps STONITH device:
ipaddr
password